Code: 1394

LSI Stacking system including: Unscrambler Singulator High Low Chain Alternate ending Adjustable layer maker Layer forks Hoist Outfeed Packet Deck Electrics and controls Building The stacker and building is available for immediate sale and removal The plant is available for inspection and price is negotiable.

CONTACT US




Name: Jonathan McLachlan
Email:
jonathan@skookum.co.nz

Ph: +64 9 276 2402
Cell: +64 276 488 488
Web:
www.skookum.co.nz
Contact Us

Boilers & Kilns | Boiler

Code: 1372
Category:  Sawmilling  >  Used Equipment  >  Boilers & Kilns

Age: 2005
Model no: 3MW 1100 Maxitherm
Low Water Level: 40mm of visible glass
Extra Low Water Level: 25mm of visible glass
Boiler High Water: +80mm from half glass
Normal Water: Half glass
Safety valve setting: 10.3 bar
Steam modulating controller: 8.5 bar
Low Fire hold: 2 bar
HP Cutout (Internal PLC) 9.2 bar
High Steam Pressure Switch: 9.8 bar
Air Pressure switch: 5 bar F
eedtank low water: 500mm from tank bottom
Combustion chamber
temperature high: 850°C
Feedline pressure low: 6.5 bar
Boiler Low pressure Alarm: 6 bar
Fuel: Wood chip or coal - currently using wood chip